{"product_id":"abb-scg-4-75-5-current-transformer-ct-7525a29g02-600v-10kv-bil-50-400hz","title":"ABB SCG-4 75:5 Current Transformer CT 7525A29G02 600V 10kV BIL 50-400Hz","description":"\u003cp style='margin: 0px 0px 12px; font-style: normal; font-variant-caps: normal; font-width: normal; font-size: 12px; line-height: normal; font-family: \"Times New Roman\"; font-size-adjust: none; font-kerning: auto; font-variant-alternates: normal; font-variant-ligatures: normal; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-position: normal; font-variant-emoji: normal; font-feature-settings: normal; font-optical-sizing: auto; font-variation-settings: normal; -webkit-text-stroke-width: 0px; -webkit-text-stroke-color: rgb(0, 0, 0);'\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eABB SCG-4 75:5 Current Transformer CT 7525A29G02 600V 10kV BIL 50-400Hz\u003c\/span\u003e\u003c\/p\u003e\u003cdiv\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003e\u003cp style=\"margin: 0.0px 0.0px 14.0px 0.0px; font: 14.0px 'Times New Roman'; -webkit-text-stroke: #000000\"\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eDescription\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0.0px 0.0px 12.0px 0.0px; font: 12.0px 'Times New Roman'; -webkit-text-stroke: #000000\"\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eABB SCG-4 Current Transformer – 75:5A – 7525A29G02\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0.0px 0.0px 12.0px 0.0px; font: 12.0px 'Times New Roman'; -webkit-text-stroke: #000000\"\u003e\u003cspan style=\"font-kerning: none;\"\u003eGenuine ABB ring-type current transformer for industrial electrical, switchgear, metering, monitoring, and power distribution applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0.0px 0.0px 12.0px 0.0px; font: 12.0px 'Times New Roman'; -webkit-text-stroke: #000000\"\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003ePart \/ Style Number:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e 7525A29G02\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eModel \/ Type:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e SCG-4\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eCurrent Ratio:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e 75:5 A\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eManufacturer:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e ABB\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eFrequency:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e 50–400 Hz\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eVoltage Class:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e 600 V insulation class\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eBIL:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e 10 kV\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eSecondary:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e 5 A\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eConstruction:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e Ring \/ window-type current transformer\u003cbr\u003e\n\u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003eSecondary Connections:\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e Two brass stud terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0.0px 0.0px 12.0px 0.0px; font: 12.0px 'Times New Roman'; -webkit-text-stroke: #000000\"\u003e\u003cspan style=\"font-kerning: none;\"\u003eABB SCG-series documentation describes these units as 600 V indoor current transformers with 10 kV BIL, an impact-resistant polycarbonate case, toroidally wound core and distributed secondary winding. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0.0px 0.0px 12.0px 0.0px; font: 12.0px 'Times New Roman'; -webkit-text-stroke: #000000\"\u003e\u003cspan style=\"font-kerning: none;\"\u003eThe ABB reference information specifically identifies \u003c\/span\u003e\u003cspan style=\"font-family: TimesNewRomanPS-BoldMT; font-weight: bold; font-kerning: none;\"\u003e75 A primary \/ 5 A secondary SCG-4 as style 7525A29G02\u003c\/span\u003e\u003cspan style=\"font-kerning: none;\"\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0.0px 0.0px 12.0px 0.0px; font: 12.0px 'Times New Roman'; -webkit-text-stroke: #000000\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53417871769889,"sku":"TARIMA 109","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/5974\/7617\/files\/57_2a8e79fd-6307-4e48-9814-dea491d8125e.jpg?v=1788196353","url":"https:\/\/www.multisurplus.com\/products\/abb-scg-4-75-5-current-transformer-ct-7525a29g02-600v-10kv-bil-50-400hz","provider":"MULTISURPLUS","version":"1.0","type":"link"}